001

Contact HMS Store Manager

Goto HMS-Brightsign Home Page

Contact HMS Technical Support

BrightSign Interface Products

Brightsign RS232 'Serial Port' Interface Board

 

RS232-20x20 Interface

16 Input, 16 Output RS232 (Serial Interface Board)

RS232-16x16

Features:

Operation:

This Firmware allows for multiple inputs low at the same time.  I.E. If input 1 goes low ('1' is reported), then input 2 goes low (while input 1 is held low), then input 2 will be reported.  If any 'active' Input (switch) opens then closes, it will be reported as a new input. I.E. suppose input1 is closed and input2 is closed and opened multiple times.  A '2' will be sent with each successive switch closure.  This logic is for all inputs.  With Rev 2.x firmware, a single switch can be used to show closed and open.  If you want to detect a door or drawer opening and then closing, arrange the switch to close when the door or drawer opens, and then the switch opens when the door or drawer is closed.  

*********Output Control Commands (Lights):

HMS Protocol for Controlling Outputs:

Outputs: Connect Loads between 'Output' and +V.

Inputs:

When any input goes low (button input), then a string is sent to the BrightSign (or other RS232 device).

The strings are:

    Input# = String

Not HMS Protocol for Controlling the board SW1-1 = ON:

The first byte received sets output port1 (outputs 1-8), the second byte received sets output port2 (outputs 9-16).  Each byte after byte 2 discarded.
I.E. Send this byte sequence [1,128] and these are the results:

Note: In BrightAuthor set the Serial I/O event to ASCII (not bytes).  Baud Setting: 38400,N,8,1 (No parity, 8 bits, 1 stop bit)

Options SW1-1 to SW1-4:

Note: The 12 volt 'barrel' connector is typically rated at 2 amps.  IF you need to drive more than 2 amps, use the output connector 0V and +V to connect your power supply.

Updated: 03/02/2024